A new approach for atraumatic implant explantation and immediate implant installation

OBJECTIVE: This study reports a new approach for implant extraction in a convenient, fast, and atraumatic way and allowing a new implant placement at same surgical time. STUDY DESIGN: The Biotechnology Institute extraction kit consists of a wrench that allows a 200 N-cm countertorque force, an internal connection extractor, an extractor for external connection, and a set of ratchet handle extension pieces. In this study, a total of 91 implants installed in 42 patients were explanted. RESULTS: Extraction torques ranged from 80 to 200 N-cm. In those cases in which implant removal torques exceeded 200 N-cm, a 2-3-mm depth incision was done using a set of atraumatic trephines to avoid too high countertorque forces. CONCLUSIONS: The possibility of extracting osseointegrated implants opens new doors in oral implantology. The extraction kit allows dentists to re-treat cases and improve the final results, achieving the best outcomes for patients.

— actualidad · noticias ›

BTI Biotechnology Institute supera una década de liderazgo científico entre las bioempresas españolas

miércoles, 10 de junio de 2026

BTI Biotechnology Institute vuelve a situarse como la empresa biotecnológica española con mayor producción científica, con un total de 29 publicaciones recogidas en el Informe AseBio 2025.

Oral Surg Oral Med Oral Pathol Oral Radiol

2,012

Autores:
Anitua, E.; Orive, G.

OBJECTIVE: This study reports a new approach for implant extraction in a convenient, fast, and atraumatic way and allowing a new implant placement at same surgical time. STUDY DESIGN: The Biotechnology Institute extraction kit consists of a wrench that allows a 200 N-cm countertorque force, an internal connection extractor, an extractor for external connection, and a set of ratchet handle extension pieces. In this study, a total of 91 implants installed in 42 patients were explanted. RESULTS: Extraction torques ranged from 80 to 200 N-cm. In those cases in which implant removal torques exceeded 200 N-cm, a 2-3-mm depth incision was done using a set of atraumatic trephines to avoid too high countertorque forces. CONCLUSIONS: The possibility of extracting osseointegrated implants opens new doors in oral implantology. The extraction kit allows dentists to re-treat cases and improve the final results, achieving the best outcomes for patients.

Artículos relacionados

Continúa tu investigación a través de nuestra selección de publicaciones vinculadas. Descubre estudios complementarios que abordan áreas temáticas, enfoques clínicos o desarrollos afines, diseñados para enriquecer tu comprensión sobre este campo científico.

LESIONES NERVIOSAS

The Effectiveness of Plasma Rich in Growth Factors in the Treatment of Nerve Compression Syndromes of the Upper Extremity

Galan V, Inigo-Dendariarena I, Galan J, Prado R, Padilla S, Anitua E. J Clin Med. 2022 Aug 16;11(16):4789.

LESIONES NERVIOSAS

The Effectiveness of Plasma Rich in Growth Factors in the Treatment of Nerve Compression Syndromes of the Upper Extremity

Galan V, Inigo-Dendariarena I, Galan J, Prado R, Padilla S, Anitua E. J Clin Med. 2022 Aug 16;11(16):4789.

LESIONES NERVIOSAS

The Effectiveness of Plasma Rich in Growth Factors in the Treatment of Nerve Compression Syndromes of the Upper Extremity