AIM: The aim of this study is to evaluate the influence of crown-to-implant (CI) ratio as well as other surgical, prosthetic and biomechanical variables on marginal bone loss (MBL) and on the survival rates of implant-supported prostheses in short implants (</=8.5 mm in length) placed in posterior areas of maxilla and mandible. MATERIAL & METHODS: This was a retrospective study based on clinical charts and follow-up recordings from a single private practice over a period of 10 years. Patients rehabilitated in the posterior region of the jaws by means of prostheses supported by implants of </=8.5 mm length were included. Patients-related, surgery-related. and implant-related variables, as well as other prosthetic and biomechanical variables. were registered. The data were split into two groups according to the value of CI ratio (CI < 2 and CI >/= 2). MBL was measured from radiographs using an image analysis software. Implant and prosthesis survival rates were recorded. RESULTS: One hundred twenty-eight short implants placed in 63 patients were evaluated. The mean follow-up period was 21.88 months (standard deviation (SD): 22.9, range 7-113 months). Eighty-six implants (67.2%) had a CI ratio of <2, whereas it was >/=2 in 42 implants (32.8%). The mean value of CI ratio was 1.82 (SD: 0.42; range 1.04-3.31). The average MBL after 1 year of follow-up was 0.35 (SD: 0.50), and it was 0.45 (SD: 0.46) mm for subsequent evaluations. Survival rates of implants and prosthesis were 100%. The presence of a cantilever had a negative influence on the first year MBL (p < .05). CONCLUSIONS: The CI ratio had not a significant influence on MBL in Biotechnology Institute (BTI; Vitoria, Spain) short implants humidified with PRGF-Endoret and placed in posterior areas. The only variable that showed a significant negative influence on first year postloading MBL was the use of cantilever for rehabilitations.
— actualidad · noticias ›
miércoles, 10 de junio de 2026
BTI Biotechnology Institute vuelve a situarse como la empresa biotecnológica española con mayor producción científica, con un total de 29 publicaciones recogidas en el Informe AseBio 2025.
2,015
AIM: The aim of this study is to evaluate the influence of crown-to-implant (CI) ratio as well as other surgical, prosthetic and biomechanical variables on marginal bone loss (MBL) and on the survival rates of implant-supported prostheses in short implants (</=8.5 mm in length) placed in posterior areas of maxilla and mandible. MATERIAL & METHODS: This was a retrospective study based on clinical charts and follow-up recordings from a single private practice over a period of 10 years. Patients rehabilitated in the posterior region of the jaws by means of prostheses supported by implants of </=8.5 mm length were included. Patients-related, surgery-related. and implant-related variables, as well as other prosthetic and biomechanical variables. were registered. The data were split into two groups according to the value of CI ratio (CI < 2 and CI >/= 2). MBL was measured from radiographs using an image analysis software. Implant and prosthesis survival rates were recorded. RESULTS: One hundred twenty-eight short implants placed in 63 patients were evaluated. The mean follow-up period was 21.88 months (standard deviation (SD): 22.9, range 7-113 months). Eighty-six implants (67.2%) had a CI ratio of <2, whereas it was >/=2 in 42 implants (32.8%). The mean value of CI ratio was 1.82 (SD: 0.42; range 1.04-3.31). The average MBL after 1 year of follow-up was 0.35 (SD: 0.50), and it was 0.45 (SD: 0.46) mm for subsequent evaluations. Survival rates of implants and prosthesis were 100%. The presence of a cantilever had a negative influence on the first year MBL (p < .05). CONCLUSIONS: The CI ratio had not a significant influence on MBL in Biotechnology Institute (BTI; Vitoria, Spain) short implants humidified with PRGF-Endoret and placed in posterior areas. The only variable that showed a significant negative influence on first year postloading MBL was the use of cantilever for rehabilitations.
Selecciona el cuadro de debajo y mapéalo al campo «A quién va dirigido» del contenido actual. Cada párrafo o elemento de lista se mostrará como una tarjeta.
En BTI Biotechnology Institute, la investigación es el motor que transforma el conocimiento en soluciones clínicas reales. Avalados por más de una década liderando la producción científica biotecnológica en España y con más de 350 artículos publicados, nuestro compromiso es puramente traslacional: llevar cada descubrimiento del laboratorio directamente a la práctica médica diaria para mejorar la calidad de vida de los pacientes.
Para hacerlo posible, contamos con instalaciones de vanguardia preparadas para la máxima exigencia. En este entorno de alto rendimiento, nuestro equipo desarrolla tecnologías revolucionarias, como los avanzados sistemas de implantología o el plasma rico en factores de crecimiento (PRGF-Endoret®). Descubre cómo nuestro rigor científico nos permite innovar de forma personalizada, no solo en cirugía oral, sino en áreas tan diversas como la oftalmología, la traumatología, la medicina deportiva o la dermatología.
¡Gracias!