- PRGF - ENDORET®
- Specialità mediche
- BTI APNIA®
- Diagnosi
- Trattamento
The effects of surface modifications and bacteria on the corrosion behavior of titanium have been studied. Five surface modifications were analyzed: two acid etchings (op V, op N), acid etching + anodic oxidation (op NT), sandblasting + acid etching (SLA), and machined surfaces (mach). The corrosion behavior of the surface modifications was evaluated by following the standard ANSI/AAMI/ISO 10993-15:2000. Cyclic potentiodynamic and potentiostatic anodic polarization tests and ion release by ICP-OES after immersion for 7 days in 0.9% NaCl were carried out. Microbiologically induced corrosion (MIC) of low and high roughness (mach, op V) was assessed in situ by electrochemical techniques. Streptococcus mutans bacteria were resuspended in PBS at a concentration of 3 x 10(8) bacteria mL(-1) and maintained at 37 degrees C. MIC was measured through the open circuit potential, E(oc) , and electrochemical impedance spectroscopy from 2 to 28 days. Potentiodynamic curves showed the typical passive behavior for all the surface modifications. The titanium ion release after immersion was below 3 ppb. In situ bacteria monitoring showed the decrease in E(oc) from -0.065 (SD 0.067) V(vs. Ag/AgCl) in mach and -0.115 (SD 0.084) V(vs. Ag/AgCl) in op V, to -0.333 (SD 0.147) V(vs. Ag/AgCl) in mach and -0.263 (SD 0.005) V(vs. Ag/AgCl) in op V, after 2 and 28 days, respectively. A reduction of the oxide film resistance, especially in op V (54 MOmega cm(2) and 6 MOmega cm(2) , after 2 and 28 days, respectively) could be seen. Streptococcus mutans negatively affected the corrosion resistance of titanium.
— actualidad · noticias ›
miércoles, 10 de junio de 2026
BTI Biotechnology Institute vuelve a situarse como la empresa biotecnológica española con mayor producción científica, con un total de 29 publicaciones recogidas en el Informe AseBio 2025.
2,018
The effects of surface modifications and bacteria on the corrosion behavior of titanium have been studied. Five surface modifications were analyzed: two acid etchings (op V, op N), acid etching + anodic oxidation (op NT), sandblasting + acid etching (SLA), and machined surfaces (mach). The corrosion behavior of the surface modifications was evaluated by following the standard ANSI/AAMI/ISO 10993-15:2000. Cyclic potentiodynamic and potentiostatic anodic polarization tests and ion release by ICP-OES after immersion for 7 days in 0.9% NaCl were carried out. Microbiologically induced corrosion (MIC) of low and high roughness (mach, op V) was assessed in situ by electrochemical techniques. Streptococcus mutans bacteria were resuspended in PBS at a concentration of 3 x 10(8) bacteria mL(-1) and maintained at 37 degrees C. MIC was measured through the open circuit potential, E(oc) , and electrochemical impedance spectroscopy from 2 to 28 days. Potentiodynamic curves showed the typical passive behavior for all the surface modifications. The titanium ion release after immersion was below 3 ppb. In situ bacteria monitoring showed the decrease in E(oc) from -0.065 (SD 0.067) V(vs. Ag/AgCl) in mach and -0.115 (SD 0.084) V(vs. Ag/AgCl) in op V, to -0.333 (SD 0.147) V(vs. Ag/AgCl) in mach and -0.263 (SD 0.005) V(vs. Ag/AgCl) in op V, after 2 and 28 days, respectively. A reduction of the oxide film resistance, especially in op V (54 MOmega cm(2) and 6 MOmega cm(2) , after 2 and 28 days, respectively) could be seen. Streptococcus mutans negatively affected the corrosion resistance of titanium.
Selecciona el cuadro de debajo y mapéalo al campo «A quién va dirigido» del contenido actual. Cada párrafo o elemento de lista se mostrará como una tarjeta.
En BTI Biotechnology Institute, la investigación es el motor que transforma el conocimiento en soluciones clínicas reales. Avalados por más de una década liderando la producción científica biotecnológica en España y con más de 350 artículos publicados, nuestro compromiso es puramente traslacional: llevar cada descubrimiento del laboratorio directamente a la práctica médica diaria para mejorar la calidad de vida de los pacientes.
Para hacerlo posible, contamos con instalaciones de vanguardia preparadas para la máxima exigencia. En este entorno de alto rendimiento, nuestro equipo desarrolla tecnologías revolucionarias, como los avanzados sistemas de implantología o el plasma rico en factores de crecimiento (PRGF-Endoret®). Descubre cómo nuestro rigor científico nos permite innovar de forma personalizada, no solo en cirugía oral, sino en áreas tan diversas como la oftalmología, la traumatología, la medicina deportiva o la dermatología.
¡Gracias!