- PRGF - ENDORET®
- Specialità mediche
- BTI APNIA®
- Diagnosi
- Trattamento
Background Plasma rich in growth factors (PRGF-Endoret) is an autologous platelet enriched plasma that has been standardised for ophthalmic application. In the past years, PRGF-Endoret has been successfully used like an eye drop for the treatment of a wide range of ocular surface diseases, including dry eye, persistent corneal epithelial defects and ulcers. Current classification of autologous plasma derivatives such as human medicines imply that it has to meet all the requirements of ophthalmic preparations.Purpose To assess the galenic properties of the PRGF eye drops and its compliance with European Pharmacopoeia requirements.Material and methods Eye drops were obtained using the PRGF-Endoret ophthalmology kit. Briefly, blood was collected into 9 mL tubes, centrifuged at 580 g, plasma column was drawn off avoiding the buffy coat and incubated at 37°C with CaCl2. Supernatants were collected, filtered and aliquoted in single dose containers. Eye drops were kept fresh or stored at −20°C for 3 months. Aseptic process simulations (Media Fill) were performed using tryptic soy broth (TSB) to 6 batches. The samples were incubated for 14 days and inspected for microbial growth. A growth promotion test was done. Deliverable volume test was applied to 5 single dose containers. Oat-Water tightness test was done in two batches in duplicate with a toluidine solution and applying a vacuum for 10 min. pH and osmolarity were assessed in fresh samples and after freezing for 3 months.Results In the media fill all units were negative for growth. In the growth promotion test, growth of all the microorganisms was clearly seen. The volume of each container was within the range of 95–110%. In the first batch, no toluidine was detected inside the vials or the caps. In the second batch, only one vial had a shadow of toluidine inside the cap. pH and osmolarity values were slightly modified after freezing. Eye drops were clear and free from particles.Conclusion The PRGF-Endoret method was asepticThe water tightness of the vials was correct, and the deliverable volume corresponded with the nominal volume. pH and osmolarity remained constant during the whole period. We can affirm that PRGF-Endoret meets the European Pharmacopoeia requirements and their galenic properties.Conflict of interest:Corporate sponsored research or other substantive relationships: EA is the scientific director of BTI, and GO and FM are scientists at BTI.
— actualidad · noticias ›
miércoles, 10 de junio de 2026
BTI Biotechnology Institute vuelve a situarse como la empresa biotecnológica española con mayor producción científica, con un total de 29 publicaciones recogidas en el Informe AseBio 2025.
2,017
Background Plasma rich in growth factors (PRGF-Endoret) is an autologous platelet enriched plasma that has been standardised for ophthalmic application. In the past years, PRGF-Endoret has been successfully used like an eye drop for the treatment of a wide range of ocular surface diseases, including dry eye, persistent corneal epithelial defects and ulcers. Current classification of autologous plasma derivatives such as human medicines imply that it has to meet all the requirements of ophthalmic preparations.Purpose To assess the galenic properties of the PRGF eye drops and its compliance with European Pharmacopoeia requirements.Material and methods Eye drops were obtained using the PRGF-Endoret ophthalmology kit. Briefly, blood was collected into 9 mL tubes, centrifuged at 580 g, plasma column was drawn off avoiding the buffy coat and incubated at 37°C with CaCl2. Supernatants were collected, filtered and aliquoted in single dose containers. Eye drops were kept fresh or stored at −20°C for 3 months. Aseptic process simulations (Media Fill) were performed using tryptic soy broth (TSB) to 6 batches. The samples were incubated for 14 days and inspected for microbial growth. A growth promotion test was done. Deliverable volume test was applied to 5 single dose containers. Oat-Water tightness test was done in two batches in duplicate with a toluidine solution and applying a vacuum for 10 min. pH and osmolarity were assessed in fresh samples and after freezing for 3 months.Results In the media fill all units were negative for growth. In the growth promotion test, growth of all the microorganisms was clearly seen. The volume of each container was within the range of 95–110%. In the first batch, no toluidine was detected inside the vials or the caps. In the second batch, only one vial had a shadow of toluidine inside the cap. pH and osmolarity values were slightly modified after freezing. Eye drops were clear and free from particles.Conclusion The PRGF-Endoret method was asepticThe water tightness of the vials was correct, and the deliverable volume corresponded with the nominal volume. pH and osmolarity remained constant during the whole period. We can affirm that PRGF-Endoret meets the European Pharmacopoeia requirements and their galenic properties.Conflict of interest:Corporate sponsored research or other substantive relationships: EA is the scientific director of BTI, and GO and FM are scientists at BTI.
Selecciona el cuadro de debajo y mapéalo al campo «A quién va dirigido» del contenido actual. Cada párrafo o elemento de lista se mostrará como una tarjeta.
En BTI Biotechnology Institute, la investigación es el motor que transforma el conocimiento en soluciones clínicas reales. Avalados por más de una década liderando la producción científica biotecnológica en España y con más de 350 artículos publicados, nuestro compromiso es puramente traslacional: llevar cada descubrimiento del laboratorio directamente a la práctica médica diaria para mejorar la calidad de vida de los pacientes.
Para hacerlo posible, contamos con instalaciones de vanguardia preparadas para la máxima exigencia. En este entorno de alto rendimiento, nuestro equipo desarrolla tecnologías revolucionarias, como los avanzados sistemas de implantología o el plasma rico en factores de crecimiento (PRGF-Endoret®). Descubre cómo nuestro rigor científico nos permite innovar de forma personalizada, no solo en cirugía oral, sino en áreas tan diversas como la oftalmología, la traumatología, la medicina deportiva o la dermatología.
¡Gracias!