- PRGF - ENDORET®
- Medizinische Fachgebiete
- BTI APNIA®
- Diagnose
- Behandlung
PURPOSE: This study aimed to evaluate the influence of scan body geometry on the trueness of intraoral scanner (IOS) acquisitions. METHODS: An in vitro study was conducted using three groups of scan bodies with varying designs. Trueness was assessed by measuring deviations from a reference model obtained using a high-precision industrial scanner. Three model types were analyzed: a fully edentulous with six implants, a partially dentate with four implants, and a partially dentate with two implants. RESULTS: In all models, the reduced-length scan body (Group 2) showed the highest trueness, with the lowest mean deviations: 87 μm (6-implant model), 104 μm (4-implant model), and 10 μm (2-implant model). The standard design (Group 1) showed moderate deviations, while the more complex design with three flat surfaces (Group 3) consistently showed the highest deviations. Shorter, simpler designs performed best across all configurations. CONCLUSIONS: Scan body geometry, particularly length and head design, plays a critical role in scanning accuracy. Simplified, shorter scan bodies enhance trueness, while greater height or geometric complexity may compromise it. These findings suggest that optimizing scan body geometry-particularly reducing height-can enhance the accuracy of digital implant impressions, with potential implications for improving reliability in implant-supported prosthetic workflows.
— actualidad · noticias ›
miércoles, 10 de junio de 2026
BTI Biotechnology Institute vuelve a situarse como la empresa biotecnológica española con mayor producción científica, con un total de 29 publicaciones recogidas en el Informe AseBio 2025.
2,025
PURPOSE: This study aimed to evaluate the influence of scan body geometry on the trueness of intraoral scanner (IOS) acquisitions. METHODS: An in vitro study was conducted using three groups of scan bodies with varying designs. Trueness was assessed by measuring deviations from a reference model obtained using a high-precision industrial scanner. Three model types were analyzed: a fully edentulous with six implants, a partially dentate with four implants, and a partially dentate with two implants. RESULTS: In all models, the reduced-length scan body (Group 2) showed the highest trueness, with the lowest mean deviations: 87 μm (6-implant model), 104 μm (4-implant model), and 10 μm (2-implant model). The standard design (Group 1) showed moderate deviations, while the more complex design with three flat surfaces (Group 3) consistently showed the highest deviations. Shorter, simpler designs performed best across all configurations. CONCLUSIONS: Scan body geometry, particularly length and head design, plays a critical role in scanning accuracy. Simplified, shorter scan bodies enhance trueness, while greater height or geometric complexity may compromise it. These findings suggest that optimizing scan body geometry-particularly reducing height-can enhance the accuracy of digital implant impressions, with potential implications for improving reliability in implant-supported prosthetic workflows.
Selecciona el cuadro de debajo y mapéalo al campo «A quién va dirigido» del contenido actual. Cada párrafo o elemento de lista se mostrará como una tarjeta.
En BTI Biotechnology Institute, la investigación es el motor que transforma el conocimiento en soluciones clínicas reales. Avalados por más de una década liderando la producción científica biotecnológica en España y con más de 350 artículos publicados, nuestro compromiso es puramente traslacional: llevar cada descubrimiento del laboratorio directamente a la práctica médica diaria para mejorar la calidad de vida de los pacientes.
Para hacerlo posible, contamos con instalaciones de vanguardia preparadas para la máxima exigencia. En este entorno de alto rendimiento, nuestro equipo desarrolla tecnologías revolucionarias, como los avanzados sistemas de implantología o el plasma rico en factores de crecimiento (PRGF-Endoret®). Descubre cómo nuestro rigor científico nos permite innovar de forma personalizada, no solo en cirugía oral, sino en áreas tan diversas como la oftalmología, la traumatología, la medicina deportiva o la dermatología.
¡Gracias!