- PRGF - ENDORET®
- Medizinische Fachgebiete
- BTI APNIA®
- Diagnose
- Behandlung
The success of dental implants lies in their strong and lasting integration into the patient's receiving bone. The first biological interactions at the implant surface determine the subsequent evolution of the integration process. In this study we set our objective to analyze the mechanistic interaction of the early regenerative matrix at implant surfaces modified with calcium ions (Ca) as compared to standard implant surfaces (NoCa). We put the surfaces in a Quartz Crystal Microbalance with Dissipation (QCM-D) to monitor the frequency shift (f) and the viscoelastic properties of the adsorbed biofilms and used Scanning Electron Microscopy (SEM) to visualize the resulting interfaces. Upon the addition of human blood plasma, Ca surfaces formed an adsorbed three-dimensional film attached to the surface (∆f = -40 Hz), while with NoCa, the biofilm formed but was not attached to the surface (∆f = 0 Hz). After 20 min in blood, two representative commercial implants with Ca and NoCa surfaces showed also distinct interfaces: Ca implants formed a visible clot attached to the implant which was composed mainly of platelets (Surface Coverage: 40 +/- 20%) and some red blood cells (SC: 9 +/- 3%) entrapped within a fibrin network (SC: 93 +/- 5%). The NoCa implants were largely populated by red blood cells (SC: 67 +/- 12%) with scarce fibrin remnants (SC: 3 +/- 2%), and the implants showed no clot on their surfaces macroscopically. The pre-clinical and clinical results discussed in this work encourage the modification of titanium implant surfaces with calcium ions to improve the bone regenerative process. Taken together, these results add more information about the roles of Ca ions in bridging the formation of the provisional matrix at implant surfaces and their effects on implant osseointegration.
— actualidad · noticias ›
miércoles, 10 de junio de 2026
BTI Biotechnology Institute vuelve a situarse como la empresa biotecnológica española con mayor producción científica, con un total de 29 publicaciones recogidas en el Informe AseBio 2025.
2,022
The success of dental implants lies in their strong and lasting integration into the patient's receiving bone. The first biological interactions at the implant surface determine the subsequent evolution of the integration process. In this study we set our objective to analyze the mechanistic interaction of the early regenerative matrix at implant surfaces modified with calcium ions (Ca) as compared to standard implant surfaces (NoCa). We put the surfaces in a Quartz Crystal Microbalance with Dissipation (QCM-D) to monitor the frequency shift (f) and the viscoelastic properties of the adsorbed biofilms and used Scanning Electron Microscopy (SEM) to visualize the resulting interfaces. Upon the addition of human blood plasma, Ca surfaces formed an adsorbed three-dimensional film attached to the surface (∆f = -40 Hz), while with NoCa, the biofilm formed but was not attached to the surface (∆f = 0 Hz). After 20 min in blood, two representative commercial implants with Ca and NoCa surfaces showed also distinct interfaces: Ca implants formed a visible clot attached to the implant which was composed mainly of platelets (Surface Coverage: 40 +/- 20%) and some red blood cells (SC: 9 +/- 3%) entrapped within a fibrin network (SC: 93 +/- 5%). The NoCa implants were largely populated by red blood cells (SC: 67 +/- 12%) with scarce fibrin remnants (SC: 3 +/- 2%), and the implants showed no clot on their surfaces macroscopically. The pre-clinical and clinical results discussed in this work encourage the modification of titanium implant surfaces with calcium ions to improve the bone regenerative process. Taken together, these results add more information about the roles of Ca ions in bridging the formation of the provisional matrix at implant surfaces and their effects on implant osseointegration.
Selecciona el cuadro de debajo y mapéalo al campo «A quién va dirigido» del contenido actual. Cada párrafo o elemento de lista se mostrará como una tarjeta.
En BTI Biotechnology Institute, la investigación es el motor que transforma el conocimiento en soluciones clínicas reales. Avalados por más de una década liderando la producción científica biotecnológica en España y con más de 350 artículos publicados, nuestro compromiso es puramente traslacional: llevar cada descubrimiento del laboratorio directamente a la práctica médica diaria para mejorar la calidad de vida de los pacientes.
Para hacerlo posible, contamos con instalaciones de vanguardia preparadas para la máxima exigencia. En este entorno de alto rendimiento, nuestro equipo desarrolla tecnologías revolucionarias, como los avanzados sistemas de implantología o el plasma rico en factores de crecimiento (PRGF-Endoret®). Descubre cómo nuestro rigor científico nos permite innovar de forma personalizada, no solo en cirugía oral, sino en áreas tan diversas como la oftalmología, la traumatología, la medicina deportiva o la dermatología.
¡Gracias!