Indications / Advantages

A tapered implant design that supports progressive, controlled insertion, with considerable versatility for adaptation to most clinical scenarios, including those with reduced interdental spaces. Its narrow prosthetic emergence profile facilitates management of the peri-implant tissues while maintaining sufficient resistance to the biomechanical demands of the restoration.

Design of BTI CORE® implants

Connection and prosthetic platform

Its internal tetralobed connection features an edge-free geometry that reduces stress concentration points and promotes uniform distribution of axial, lateral and torsional loads. This design minimises the risk of plastic deformation during implant insertion and removal and facilitates the precise placement of prosthetic components.

Occlusal view of the connection
Perspective view of the prosthetic platform

Apex

Cylindrical apex (short and extra-short implants): designed to provide greater control over implant advancement and positioning, reducing the risk of injury to adjacent anatomical structures, such as the maxillary sinus or the inferior alveolar nerve. Its broad apical surface supports good primary stability without generating excessive bone compression.

Tapered apex (implants longer than 6.5 mm): facilitates insertion in different bone types owing to its greater advancement capacity, supporting high primary stability.

Detail of the cylindrical apex
Detail of the conical apex

Range of diameters and lengths

The BTI CORE® implant range is available in six body diameters and different lengths, from 4.5 to 15 mm, depending on the selected diameter. This broad range provides considerable clinical versatility, allowing treatment to be tailored to each patient’s anatomical conditions and enabling the management of most routine implantology scenarios.

Available BTI CORE® diameters
Available BTI CORE® lengths

Advantages of BTI CORE® system

Ventajas del sistema CORE-X
  • UNICCA® surface

    The UNICCA® surface of BTI implants combines a chemical modification with calcium ions and three levels of roughness adapted to each area of the implant: reduced at the neck, moderate at the body and increased at the threads. This design promotes osseointegration and contributes to reducing bacterial adhesion. Certified purity. BTI implants bear the quality seal of the CleanImplant Foundation, certifying compliance with stringent surface cleanliness criteria.

  • Surgery: reduced KCQ5 surgical kit

    Surgical kit designed for the placement of BTI CORE® and CORE-X® implants using simplified drilling protocols, with a reduced number of drills that facilitates the surgical procedure and helps optimise operative time and associated costs.

  • Prosthetics

    It allows single and multiple restorations to be performed, either directly on the implant or by means of a transepithelial component (intermediate abutment), with full prosthetic component compatibility across the CORE-X® range. Exception: 4.5 mm-long implants are indicated exclusively for multiple screw-retained restorations by means of specific MULTI-IM® transepithelial components; single restorations and those performed directly on the implant are excluded.

  • BIOBLOCK® concept

    BIOBLOCK® is a biomechanical concept which, from a single prosthetic connection, allows the use of a wide range of intermediate abutments (transepithelial components) with different heights and configurations, whether straight or expanded. This versatility allows the emergence profile to be adapted to the requirements of each clinical situation, optimising the biological and biomechanical conditions to support peri-implant tissue stability and preservation of the marginal bone.

  • Protocolo de fresado menos invasivo

    Fresado simplificado, usando fresas más estrechas y logrando buena estabilidad.

  • Texto de ejemplo

    Texto de ejemplo

Supporting material

Resources

Guía rápida

Guía rápida interna y de referencias BTI CORE®

Esta guía muestra las soluciones que BTI ofrece al profesional para enfrentarse a las diferentes situaciones quirúrgico-protésicas.

BTI Channel

Webinar BTI CORE® por el Dr. Eduardo Anitua

En este webinar se abordan los últimos avances en el desarrollo de la superficie, la biomecánica y los aspectos clave durante el fresado biológico.

Formación

BTI Implant System - Iniciación

Adéntrate con este curso en la metodología de trabajo BTI y conoce de primera mano toda la tecnología que pone a tu alcance.

BTI al día

Preguntas frecuentes de los expertos

¿Cómo influyen las características de la superficie del implante (rugosidad, tratamiento químico) en la osteointegración a largo plazo?

La superficie UNICCA® de los implantes BTI CORE® combina tres niveles de rugosidad adaptados a las diferentes zonas del implante con una modificación química mediante iones de calcio. Esta combinación favorece la interacción con el tejido óseo desde las primeras fases de cicatrización, creando condiciones favorables para la osteointegración y la estabilidad biológica del implante a largo plazo.

¿Qué factores pueden influir en el éxito o fracaso de un implante?

Texto de ejemplo

¿Cuánto tiempo tarda en integrarse un implante con el hueso?

Texto de ejemplo

¿Qué diferencias existen entre los distintos tipos de implantes disponibles?

Texto de ejemplo

¿Qué complicaciones pueden surgir después de la colocación de un implante y cómo se previenen?

Texto de ejemplo

Texto de ejemplo

Texto de ejemplo

Texto de ejemplo

Texto de ejemplo

Texto de ejemplo

Texto de ejemplo

Texto de ejemplo

Texto de ejemplo

Texto de ejemplo

Texto de ejemplo

Contact us

Close-up
Nombre

Apellidos

Email

¿Cómo quieres que contactemos contigo? *

Teléfono

Código postal

País

Escribe aquí tu consulta *