- PRGF - ENDORET®
- Medical specialties
- BTI APNIA®
- Diagnosis
- Treatment

Minimally invasive explantation. Maximum bone preservation for implant retreatment.

Indications / Advantages
KEXIM is an explantation system designed to remove osseointegrated implants using a controlled countertorque technique, minimising trauma to the implant site and promoting its preservation for subsequent restoration.

The kit includes a precise counter-torque wrench (up to 200 Ncm), single-use extractors adaptable to different implants, burs for connection preparation, and a carrier handle (MDPT), providing everything required for safe explantation.
It significantly reduces surgical time and increases the predictability of re-treatment.
Its atraumatic approach is critical for maintaining bone architecture, thereby supporting subsequent rehabilitation options.
The single-use nature of the extractors ensures that the frictional properties and geometry of each component are intact in every procedure. This prevents any failure due to material wear and ensures that torque is transmitted to the implant with maximum effectiveness.
The incorporation of dedicated extenders for the counter-torque wrench greatly facilitates clinical manoeuvrability. This allows the required force to be applied comfortably, precisely and safely, even in posterior sectors or in the most difficult-to-access areas of the oral cavity.
Texto de ejemplo
Quick guide
Discover the complete list of more than 35 implant systems compatible with the extraction kit
BTI Channel
In this webinar, we present the key points for performing explantation rapidly,
Training
Learn predictable surgical and maintenance protocols to save compromised implants and
KEXIM is designed to work with both internal- and external-connection implants. The extraction kit is currently universal and compatible with more than 35 different implant systems.
Yes, provided that the clinical conditions allow it. The KEXIM® countertorque technique promotes peri-implant bone preservation, facilitating the immediate placement of a new implant. However, the case must be reassessed, taking into account the cause of the previous implant failure, the presence of infection, the volume and quality of the residual bone, and the possibility of achieving adequate primary stability. When these factors are favourable, immediate implant placement can reduce treatment time and avoid a second surgical intervention.
If osseointegration is severe and exceeds 200 Ncm, the system can be supplemented with ultra-thin cutting trephine burs. Superficial trephination of only 2–5 mm reduces the maximum torque required by more than half, ensuring successful explantation without damaging the bone architecture.
Yes. The kit addresses complications of mechanical origin specifically. It includes extractors expressly designed for the removal of implants in which the fractured screw has remained lodged inside, allowing the situation to be resolved without additional complications.
No. The extractors included in the kit are single-use. Because they are discarded after each procedure, the geometry of the component is protected from wear and its frictional capacity to transmit counter-torque force is maintained intact in a predictable and safe manner.
Texto de ejemplo
Texto de ejemplo
Texto de ejemplo
Texto de ejemplo
Texto de ejemplo
¡Gracias!
BTI al día
Permite recuperar hueso durante el fresado y, por lo tanto, que este sea utilizado como autoinjerto particulado cuando se mezcla con el plasma del paciente, que se obtiene con la tecnología PRGF – ENDORET®.
Texto de ejemplo
Texto de ejemplo
Texto de ejemplo
Texto de ejemplo
Texto de ejemplo
Texto de ejemplo
Texto de ejemplo
Texto de ejemplo
Texto de ejemplo