Surface

Hydrophilicity of UNICCA®

The high hydrophilicity of the UNICCA® surface promotes immediate contact with the biological components of blood, creating a favourable environment for the adhesion and activity of osteogenic cells and promoting the early stages of osseointegration.

Formación postgrado

Neck attenuated roughness

It promotes adaptation and stability of the peri-implant tissues in the cervical region of the implant, helping to limit bacterial adhesion.

Cursos en el instituto Eduardo Anitua

Threads high roughness

It promotes contact and integration of bone tissue with the surface of the implant threads, helping to improve implant anchorage and stability.

Cursos y colaboraciones

Valleys medium roughness

They promote bone formation and growth between the implant threads, maintaining a balance between the biological response and the mechanical properties of the implant.

Título card 4

Descripción card 4

Título card 5

Descripción card 5

Título card 6

Descripción card 6

Título card 7

Descripción card 7

Título card 8

Descripción card 8

Título card 9

Descripción card 9

Título card 10

Descripción card 10

Advantages of UNICCA® surface

Ventajas del sistema CORE-X
  • Electropositive, clean and hydrophilic

    It allows the superhydrophilic properties to be maintained thanks to the calcium ions

  • Osteogenic

    It induces bone tissue formation

  • Promoting peri-implant bone stability

    It reduces implant failure

  • Minimises bacterial adhesion

    (In vitro studies)*
    [*] Eduardo Anitua, Ricardo Tejero, Miguel Angel Pacha-Olivenza, Marıa Coronada Fernandez-Calderon, Marıa Delgado-Rastrollo, Mari Mar Zalduendo; Wiley Online Library 2017 Jan. DOI: 10.1002/jbm.b.33860

  • UNICCA® is osteogenic: it induces bone tissue formation

    Consequence: it accelerates and enhances osseointegration in all bone types (in vivo studies). [2, 6, 12, 13]

  • Texto de ejemplo

    Texto de ejemplo

UNICCA®surface

CleanImplant seal

The BTI® implant system with UNICCA® surface stands out as the first on the market to obtain the CleanImplant Foundation seal. This recognition is awarded after evaluating the quality of the materials used, as well as the cleanliness and purity of the dental implants.

Key aspects of this certification:
  • Guarantee of purity: the foundation distinguishes companies that maintain strict quality controls, ensuring sterile products free from impurities.
  • Confidence for clinicians and patients: the seal serves as a hallmark of high quality and complete confidence for professionals and their patients.
  • Validity: the “Trusted Quality Mark” quality label for BTI Biotechnology UNICCA® covers the period 2017–2026.
Editorial científica

CleanImplant Seal

The BTI® implant system with UNICCA® surface stands out as the first on the market to obtain the CleanImplant Foundation seal. This recognition is awarded after evaluating the quality of the materials used, as well as the cleanliness and purity of the dental implants.

Key aspects of this certification

Ventajas del sistema CORE-X
  • Guarantee of purity

    The foundation distinguishes companies that maintain strict quality controls, ensuring sterile products free from impurities.

  • Confidence for clinicians and patients

    The seal serves as a hallmark of high quality and complete confidence for professionals and their patients.

  • Validity

    The “Trusted Quality Mark” quality label for BTI Biotechnology UNICCA® covers the period 2017–2026.

  • Conexión de plataforma 3.5 mm

    Plana, tetralobulada y sin aristas, compatible con gama BTI-CORE®.

  • Protocolo de fresado menos invasivo

    Fresado simplificado, usando fresas más estrechas y logrando buena estabilidad.

  • Texto de ejemplo

    Texto de ejemplo

THE PERFECT DUO

BTI® Implants + PRGF - ENDORET®

The application of PRGF - ENDORET® in liquid form to the implant bed promotes the rapid formation of a fibrin matrix in contact with the UNICCA® surface, creating a favourable biological environment for the early stages of healing and osseointegration.
Editorial científica

Scientific articles

[1] Favero R, Botticelli D, Antunes A., Martinez Sanchez R, Caroprese M, Salata L. Clin Implant Dent Relat Res 2015. doi:10.1111/cid.12311.
[2] Tejero R, Rossbach P, Keller B, Anitua E, Reviakine I. Langmuir 2013;29:902–12.
[3] Sánchez-Ilárduya MB, Trouche E, Tejero R, Orive G, Reviakine I, Anitua E. J Biomed Mater Res A 2012:1–11.
[4] Aitua E, Piñas L, Murias A, Prado R, Tejero R. Colloids Surfaces B Biointerfaces 2015. doi:10.1016/j.colsurfb.2015.04.006.
[5] Ellingsen JE. Biomaterials 1991;12:593–6.
[6] Anitua E, Tejero R, Zalduendo MM, Orive G. J Periodontol 2013;84:1180–90.
[7] Adams CS, Manseld K, Perlot RL, Shapiro IM. J Biol Chem 2001;276:20316–22.
[8] Dvorak MM, Siddiqua A, Ward DT, Carter DH, Dallas SL, Nemeth EF, et al. Proc Natl Acad Sci U S A 2004;101:5140–5.
[9] McKee MD, Nanci A. Microsc Res Tech 1996;33:141–64.
[10] Favero, Lang NP, Favero R, Carneiro Martins Neto E, Salata LA, Botticelli D. Clin Oral Implants Res. 2016 Jun 14. doi: 10.1111/clr.12906.
[11] Anitua E, Prado R, Orive G, Tejero R. J Biomed Mater Res A 2014;20072018:1–12.
[12] Tejero R, Anitua E, Orive G. Prog Polym Sci 2014;39:1406–47.
[13] Eduardo Anitua , Laura Piñas and Mohammad Hamdan Alkhraisat International Journal of Implant Dentistry (2017) 3:49 DOI 10.1186/s40729-017-0111-5
[14] Eduardo Anitua, Ricardo Tejero,Miguel Angel Pacha-Olivenza, Marıa Coronada Fernandez-Calderon, Marıa Delgado-Rastrollo, Mari Mar Zalduendo; Wiley Online Library 2017 Jan. DOI: 10.1002/jbm.b.33860

Contact us

Close-up
Nombre *

Apellidos *

Correo electrónico *

¿Cómo quieres que contactemos contigo? *

Teléfono *

Código postal *

País *

Escribe aquí tu consulta *