- PRGF - ENDORET®
- Medical specialties
- BTI APNIA®
- Diagnosis
- Treatment
Through a nasal cannula, the device records respiratory airflow. In parallel, a finger pulse oximeter monitors changes in heart rate and blood oxygen levels, accurately capturing any oxygen drop resulting from an apnoea event, while also recording the pulse plethysmography signal.
This external information is intelligently integrated with the internal sensors housed within the device itself, which the patient wears on the chest, and which measure snoring intensity, thoracic respiratory effort, and body position during sleep.
The BTI APNIA® device is designed to support both specialist and patient throughout the therapeutic process, becoming a dynamic, evolving monitoring system. Beyond its initial role in the accurate diagnosis of obstructive sleep apnoea and snoring disorders, this respiratory polygraph is an essential tool for monitoring and titration across different treatment modalities.
Once the patient begins therapy, whether with the APNIA® Intraoral Device (AID), a CPAP machine, or following surgery, the polygraph enables follow-up home studies to be performed in complete comfort. These successive tests are critical for verifying treatment efficacy under real sleep conditions. In addition, in the specific case of intraoral devices such as the AID, it facilitates the titration process, allowing the specialist to adjust the millimetres of splint advancement objectively, based on the progressive, verified reduction in apnoea indices and oxygen desaturations. In this way, BTI APNIA® ensures rigorous, personalised medical follow-up with maximum long-term clinical safety.
Sobre BTI Apnia
Sistema de diagnóstico y tratamiento para la apnea del sueño y la roncopatía. Es el único del mercado que permite la diagnosis y el posterior tratamiento. El dispositivo es fácil y cómodo de colocar por el propio paciente en su domicilio, ajustándose una cánula nasal y un pulsioxímetro en el dedo índice.
Through a nasal cannula, the device records respiratory airflow. In parallel, a finger pulse oximeter monitors changes in heart rate and blood oxygen levels, accurately capturing any oxygen drop resulting from an apnoea event, while also recording the pulse plethysmography signal.
This external information is intelligently integrated with the internal sensors housed within the device itself, which the patient wears on the chest, and which measure snoring intensity, thoracic respiratory effort, and body position during sleep.
The BTI APNIA® device is designed to support both specialist and patient throughout the therapeutic process, becoming a dynamic, evolving monitoring system. Beyond its initial role in the accurate diagnosis of obstructive sleep apnoea and snoring disorders, this respiratory polygraph is an essential tool for monitoring and titration across different treatment modalities.
Once the patient begins therapy, whether with the APNIA® Intraoral Device (AID), a CPAP machine, or following surgery, the polygraph enables follow-up home studies to be performed in complete comfort. These successive tests are critical for verifying treatment efficacy under real sleep conditions. In addition, in the specific case of intraoral devices such as the AID, it facilitates the titration process, allowing the specialist to adjust the millimetres of splint advancement objectively, based on the progressive, verified reduction in apnoea indices and oxygen desaturations. In this way, BTI APNIA® ensures rigorous, personalised medical follow-up with maximum long-term clinical safety.
Morfología del implante ideada para conseguir una mayor osteocondensación mediante un protocolo de fresado reducido.
Triple rugosidad atenuada en el cuello, moderada en el cuerpo y aumentada en las espiras, modificada con iones de calcio.
Diseñada para aumentar la estabilidad en huesos de baja densidad.
Plana, tetralobulada y sin aristas, compatible con gama BTI-CORE®.
Fresado simplificado, usando fresas más estrechas y logrando buena estabilidad.
BTI al día
Rhoncus platea donec id est massa imperdiet cras. A dictumst aliquam at non magnis. Nec dolor sed vitae scelerisque enim id urna lorem diam. Quam duis turpis dolor pellentesque ac sed massa. Lectus magna turpis.
Saber másArtículos científicos
Statement of problem: The seal at the implant-abutment connection (IAC) is crucial for ensuring implant-prosthetic function and reducing the risk of peri-implant diseases.
BTI Channel
Statement of problem: The seal at the implant-abutment connection (IAC) is crucial for ensuring implant-prosthetic function and reducing the risk of peri-implant diseases.
Formación
Statement of problem: The seal at the implant-abutment connection (IAC) is crucial for ensuring implant-prosthetic function and reducing the risk of peri-implant diseases.
BTI al día
Permite recuperar hueso durante el fresado y, por lo tanto, que este sea utilizado como autoinjerto particulado cuando se mezcla con el plasma del paciente, que se obtiene con la tecnología PRGF – ENDORET®.
Texto de ejemplo
Texto de ejemplo
Texto de ejemplo
Texto de ejemplo
Texto de ejemplo
Texto de ejemplo
Texto de ejemplo
Texto de ejemplo
Texto de ejemplo