Coarse Surface Microcavities Permit Bone Ingrowth and Improve Implant Osseointegration

Abstract

Purpose: To evaluate the effects of coarse microcavities added to micron and submicron rough implant surfaces in the implant-bone anchorage in rabbits. Materials and methods: Confocal interferometry was used to quantify roughness. Electron microscopy and energy-dispersive x-rays characterized the surfaces prior to and after implantation. X-ray photoelectron spectroscopy and contact angle determined the surface chemistry and energy, respectively. Fifteen New Zealand White rabbits received, respectively, one cavity-less (C-) and one cavity-rich (C+) implant per femoral condyle and were allowed to integrate for 2 and 8 weeks. The bone-to-implant contact (BIC), bone volume density (BVD), and removal torque (RTQ) were then analyzed. Results: The cavities produced on the surfaces were 48.4 ± 16.8 μm in diameter and 37.8 ± 36.5 μm deep (5.9% ± 1.1% surface coverage). C+ did not alter the surface chemistry or energy. In vivo, C+ implants produced more BIC and RTQ at 8 weeks (P = .002 and P = .059, respectively) and more BVD at 2 and 8 weeks postimplantation (P = .031 and P = .078, respectively). Bone tissue was observed inside the cavities of C+ both histologically and by scanning electron microscopy after implant removal. Conclusion: Unevenly distributed coarse cavities within a micron and submicron rough surface allow bone ingrowth and increase implant stability and bone-surface unions in rabbits. These results encourage the design of implants with multilevel surface topographies to improve implant-based regeneration.

— actualidad · noticias ›

BTI Biotechnology Institute supera una década de liderazgo científico entre las bioempresas españolas

miércoles, 10 de junio de 2026

BTI Biotechnology Institute vuelve a situarse como la empresa biotecnológica española con mayor producción científica, con un total de 29 publicaciones recogidas en el Informe AseBio 2025.

Int J Oral Maxillofac Implants

2,022

Autores:
Anitua, E.; Tejero, R.

Abstract

Purpose: To evaluate the effects of coarse microcavities added to micron and submicron rough implant surfaces in the implant-bone anchorage in rabbits. Materials and methods: Confocal interferometry was used to quantify roughness. Electron microscopy and energy-dispersive x-rays characterized the surfaces prior to and after implantation. X-ray photoelectron spectroscopy and contact angle determined the surface chemistry and energy, respectively. Fifteen New Zealand White rabbits received, respectively, one cavity-less (C-) and one cavity-rich (C+) implant per femoral condyle and were allowed to integrate for 2 and 8 weeks. The bone-to-implant contact (BIC), bone volume density (BVD), and removal torque (RTQ) were then analyzed. Results: The cavities produced on the surfaces were 48.4 ± 16.8 μm in diameter and 37.8 ± 36.5 μm deep (5.9% ± 1.1% surface coverage). C+ did not alter the surface chemistry or energy. In vivo, C+ implants produced more BIC and RTQ at 8 weeks (P = .002 and P = .059, respectively) and more BVD at 2 and 8 weeks postimplantation (P = .031 and P = .078, respectively). Bone tissue was observed inside the cavities of C+ both histologically and by scanning electron microscopy after implant removal. Conclusion: Unevenly distributed coarse cavities within a micron and submicron rough surface allow bone ingrowth and increase implant stability and bone-surface unions in rabbits. These results encourage the design of implants with multilevel surface topographies to improve implant-based regeneration.

Artículos relacionados

Continúa tu investigación a través de nuestra selección de publicaciones vinculadas. Descubre estudios complementarios que abordan áreas temáticas, enfoques clínicos o desarrollos afines, diseñados para enriquecer tu comprensión sobre este campo científico.

LESIONES NERVIOSAS

The Effectiveness of Plasma Rich in Growth Factors in the Treatment of Nerve Compression Syndromes of the Upper Extremity

Galan V, Inigo-Dendariarena I, Galan J, Prado R, Padilla S, Anitua E. J Clin Med. 2022 Aug 16;11(16):4789.

LESIONES NERVIOSAS

The Effectiveness of Plasma Rich in Growth Factors in the Treatment of Nerve Compression Syndromes of the Upper Extremity

Galan V, Inigo-Dendariarena I, Galan J, Prado R, Padilla S, Anitua E. J Clin Med. 2022 Aug 16;11(16):4789.

LESIONES NERVIOSAS

The Effectiveness of Plasma Rich in Growth Factors in the Treatment of Nerve Compression Syndromes of the Upper Extremity

Galan V, Inigo-Dendariarena I, Galan J, Prado R, Padilla S, Anitua E. J Clin Med. 2022 Aug 16;11(16):4789.

Contacta

Close-up
Nombre *

Apellidos *

Correo electrónico *

¿Cómo quieres que contactemos contigo? *

Teléfono *

Código postal *

País *

Escribe aquí tu consulta *