The APNIA Intraoral Device (DIA) stands out for its optimal fit and retention, ensuring maximum patient comfort, thanks to a design with minimal vertical dimension and submillimetre thicknesses that reduce the impact on the temporomandibular joint (TMJ). Its intelligent design, supported by an Artificial Intelligence (AI) algorithm that analyses each patient’s requirements, ensures millimetric precision.
In addition, it stands out for its durability, as it is manufactured from a highly resilient material capable of withstanding daily mechanical loading and fatigue associated with prolonged use (certified under ISO 10993), while providing triaxial freedom of movement that reduces friction and absorbs impacts.
As an added benefit to help prevent changes in occlusion, the treatment includes a stabilisation splint, which the patient wears for 5–10 minutes after waking to help the condyle reposition the mandible rapidly into centric relation.
The manufacturing process is based on proprietary digital design and manufacturing technology carried out at the HTL CAD/CAM-Lab production centre, which provides a 2-year quality guarantee. The workflow begins with acquisition of the models in .STL or .PLY format, either through direct intraoral scanning or by means of a desktop scanner, after which they are processed using exclusive software that acts as a functional virtual articulator adapted to the patient’s biomechanics. Occlusal design and adjustment are micrometric, employing an insertion vector that simulates the exact seating of the splint in the mouth and avoids the need for subsequent adjustments.
Finally, all splints are produced using sophisticated additive manufacturing technology, with a material of controlled porosity and responsiveness to thermal stimuli, which increases its flexibility and comfort once body temperature is reached.
Sobre BTI Apnia
Sistema de diagnóstico y tratamiento para la apnea del sueño y la roncopatía. Es el único del mercado que permite la diagnosis y el posterior tratamiento. El dispositivo es fácil y cómodo de colocar por el propio paciente en su domicilio, ajustándose una cánula nasal y un pulsioxímetro en el dedo índice.
The APNIA Intraoral Device (DIA) stands out for its optimal fit and retention, ensuring maximum patient comfort, thanks to a design with minimal vertical dimension and submillimetre thicknesses that reduce the impact on the temporomandibular joint (TMJ). Its intelligent design, supported by an Artificial Intelligence (AI) algorithm that analyses each patient’s requirements, ensures millimetric precision.
In addition, it stands out for its durability, as it is manufactured from a highly resilient material capable of withstanding daily mechanical loading and fatigue associated with prolonged use (certified under ISO 10993), while providing triaxial freedom of movement that reduces friction and absorbs impacts.
As an added benefit to help prevent changes in occlusion, the treatment includes a stabilisation splint, which the patient wears for 5–10 minutes after waking to help the condyle reposition the mandible rapidly into centric relation.
The manufacturing process is based on proprietary digital design and manufacturing technology carried out at the HTL CAD/CAM-Lab production centre, which provides a 2-year quality guarantee. The workflow begins with acquisition of the models in .STL or .PLY format, either through direct intraoral scanning or by means of a desktop scanner, after which they are processed using exclusive software that acts as a functional virtual articulator adapted to the patient’s biomechanics. Occlusal design and adjustment are micrometric, employing an insertion vector that simulates the exact seating of the splint in the mouth and avoids the need for subsequent adjustments.
Finally, all splints are produced using sophisticated additive manufacturing technology, with a material of controlled porosity and responsiveness to thermal stimuli, which increases its flexibility and comfort once body temperature is reached.
Morfología del implante ideada para conseguir una mayor osteocondensación mediante un protocolo de fresado reducido.
Triple rugosidad atenuada en el cuello, moderada en el cuerpo y aumentada en las espiras, modificada con iones de calcio.
Diseñada para aumentar la estabilidad en huesos de baja densidad.
Plana, tetralobulada y sin aristas, compatible con gama BTI-CORE®.
Fresado simplificado, usando fresas más estrechas y logrando buena estabilidad.
BTI al día
Rhoncus platea donec id est massa imperdiet cras. A dictumst aliquam at non magnis. Nec dolor sed vitae scelerisque enim id urna lorem diam. Quam duis turpis dolor pellentesque ac sed massa. Lectus magna turpis.
Saber másArtículos científicos
Statement of problem: The seal at the implant-abutment connection (IAC) is crucial for ensuring implant-prosthetic function and reducing the risk of peri-implant diseases.
BTI Channel
Statement of problem: The seal at the implant-abutment connection (IAC) is crucial for ensuring implant-prosthetic function and reducing the risk of peri-implant diseases.
Formación
Statement of problem: The seal at the implant-abutment connection (IAC) is crucial for ensuring implant-prosthetic function and reducing the risk of peri-implant diseases.
BTI al día
Permite recuperar hueso durante el fresado y, por lo tanto, que este sea utilizado como autoinjerto particulado cuando se mezcla con el plasma del paciente, que se obtiene con la tecnología PRGF – ENDORET®.
Texto de ejemplo
Texto de ejemplo
Texto de ejemplo
Texto de ejemplo
Texto de ejemplo
Texto de ejemplo
Texto de ejemplo
Texto de ejemplo
Texto de ejemplo