Single-Unit Short Implants in the Molar Region: A Retrospective Study with a Minimum 3-Year Follow-up

Abstract: The high biomechanical loads in molar region wounds challenge the indication for short implants to be used as a single-unit implant. This study reports on the outcomes of single-unit short implants (≤ 8.0 mm) in the maxillary and mandibular molar regions. Forty-nine short implants were placed in 48 patients to replace a missing molar tooth. Two-piece restorations with screw retention were fabricated. During the follow-up, implant survival and marginal bone loss (MBL) were assessed. The known implant length was used as a reference to calibrate the linear measurements on digital periapical radiographs, and descriptive statistical analysis was performed. The implants were followed over a period of 47 ± 12 months. No implant failure was recorded, and no prosthesis failure was observed. The average MBL was 0.15 ± 0.5 mm. The mean crown height space was 13 ± 3 mm. The overall crown-to-implant ratio was 1.7 ± 0.4. Two technical complications occurred due to the loosening of the unit abutment. After screw re-tightening, no more screw loosening was observed. This study supports the use of short implants as a single-unit implant in the maxillary and mandibular molar regions.

— actualidad · noticias ›

BTI Biotechnology Institute supera una década de liderazgo científico entre las bioempresas españolas

miércoles, 10 de junio de 2026

BTI Biotechnology Institute vuelve a situarse como la empresa biotecnológica española con mayor producción científica, con un total de 29 publicaciones recogidas en el Informe AseBio 2025.

Int J Periodontics Restorative Dent

2,022

Autores:
Javier Flores,Sofia Fernandez de Retana, Mohammad Hamdan Alkhraisat
Abstract: The high biomechanical loads in molar region wounds challenge the indication for short implants to be used as a single-unit implant. This study reports on the outcomes of single-unit short implants (≤ 8.0 mm) in the maxillary and mandibular molar regions. Forty-nine short implants were placed in 48 patients to replace a missing molar tooth. Two-piece restorations with screw retention were fabricated. During the follow-up, implant survival and marginal bone loss (MBL) were assessed. The known implant length was used as a reference to calibrate the linear measurements on digital periapical radiographs, and descriptive statistical analysis was performed. The implants were followed over a period of 47 ± 12 months. No implant failure was recorded, and no prosthesis failure was observed. The average MBL was 0.15 ± 0.5 mm. The mean crown height space was 13 ± 3 mm. The overall crown-to-implant ratio was 1.7 ± 0.4. Two technical complications occurred due to the loosening of the unit abutment. After screw re-tightening, no more screw loosening was observed. This study supports the use of short implants as a single-unit implant in the maxillary and mandibular molar regions.

Artículos relacionados

Continúa tu investigación a través de nuestra selección de publicaciones vinculadas. Descubre estudios complementarios que abordan áreas temáticas, enfoques clínicos o desarrollos afines, diseñados para enriquecer tu comprensión sobre este campo científico.

LESIONES NERVIOSAS

The Effectiveness of Plasma Rich in Growth Factors in the Treatment of Nerve Compression Syndromes of the Upper Extremity

Galan V, Inigo-Dendariarena I, Galan J, Prado R, Padilla S, Anitua E. J Clin Med. 2022 Aug 16;11(16):4789.

LESIONES NERVIOSAS

The Effectiveness of Plasma Rich in Growth Factors in the Treatment of Nerve Compression Syndromes of the Upper Extremity

Galan V, Inigo-Dendariarena I, Galan J, Prado R, Padilla S, Anitua E. J Clin Med. 2022 Aug 16;11(16):4789.

LESIONES NERVIOSAS

The Effectiveness of Plasma Rich in Growth Factors in the Treatment of Nerve Compression Syndromes of the Upper Extremity

Galan V, Inigo-Dendariarena I, Galan J, Prado R, Padilla S, Anitua E. J Clin Med. 2022 Aug 16;11(16):4789.

Contacta

Close-up
Nombre *

Apellidos *

Correo electrónico *

¿Cómo quieres que contactemos contigo? *

Teléfono *

Código postal *

País *

Escribe aquí tu consulta *