Corrosion behavior of surface modifications on titanium dental implant. In situ bacteria monitoring by electrochemical techniques

The effects of surface modifications and bacteria on the corrosion behavior of titanium have been studied. Five surface modifications were analyzed: two acid etchings (op V, op N), acid etching + anodic oxidation (op NT), sandblasting + acid etching (SLA), and machined surfaces (mach). The corrosion behavior of the surface modifications was evaluated by following the standard ANSI/AAMI/ISO 10993-15:2000. Cyclic potentiodynamic and potentiostatic anodic polarization tests and ion release by ICP-OES after immersion for 7 days in 0.9% NaCl were carried out. Microbiologically induced corrosion (MIC) of low and high roughness (mach, op V) was assessed in situ by electrochemical techniques. Streptococcus mutans bacteria were resuspended in PBS at a concentration of 3 x 10(8) bacteria mL(-1) and maintained at 37 degrees C. MIC was measured through the open circuit potential, E(oc) , and electrochemical impedance spectroscopy from 2 to 28 days. Potentiodynamic curves showed the typical passive behavior for all the surface modifications. The titanium ion release after immersion was below 3 ppb. In situ bacteria monitoring showed the decrease in E(oc) from -0.065 (SD 0.067) V(vs. Ag/AgCl) in mach and -0.115 (SD 0.084) V(vs. Ag/AgCl) in op V, to -0.333 (SD 0.147) V(vs. Ag/AgCl) in mach and -0.263 (SD 0.005) V(vs. Ag/AgCl) in op V, after 2 and 28 days, respectively. A reduction of the oxide film resistance, especially in op V (54 MOmega cm(2) and 6 MOmega cm(2) , after 2 and 28 days, respectively) could be seen. Streptococcus mutans negatively affected the corrosion resistance of titanium.

— actualidad · noticias ›

BTI Biotechnology Institute supera una década de liderazgo científico entre las bioempresas españolas

miércoles, 10 de junio de 2026

BTI Biotechnology Institute vuelve a situarse como la empresa biotecnológica española con mayor producción científica, con un total de 29 publicaciones recogidas en el Informe AseBio 2025.

J Biomed Mater Res B Appl Biomater

2,018

Autores:
Diaz, I.; Pacha-Olivenza, M. A.; Tejero, R.; Anitua, E.; Gonzalez-Martin, M. L.; Escudero, M. L.; Garcia-Alonso, M. C.

The effects of surface modifications and bacteria on the corrosion behavior of titanium have been studied. Five surface modifications were analyzed: two acid etchings (op V, op N), acid etching + anodic oxidation (op NT), sandblasting + acid etching (SLA), and machined surfaces (mach). The corrosion behavior of the surface modifications was evaluated by following the standard ANSI/AAMI/ISO 10993-15:2000. Cyclic potentiodynamic and potentiostatic anodic polarization tests and ion release by ICP-OES after immersion for 7 days in 0.9% NaCl were carried out. Microbiologically induced corrosion (MIC) of low and high roughness (mach, op V) was assessed in situ by electrochemical techniques. Streptococcus mutans bacteria were resuspended in PBS at a concentration of 3 x 10(8) bacteria mL(-1) and maintained at 37 degrees C. MIC was measured through the open circuit potential, E(oc) , and electrochemical impedance spectroscopy from 2 to 28 days. Potentiodynamic curves showed the typical passive behavior for all the surface modifications. The titanium ion release after immersion was below 3 ppb. In situ bacteria monitoring showed the decrease in E(oc) from -0.065 (SD 0.067) V(vs. Ag/AgCl) in mach and -0.115 (SD 0.084) V(vs. Ag/AgCl) in op V, to -0.333 (SD 0.147) V(vs. Ag/AgCl) in mach and -0.263 (SD 0.005) V(vs. Ag/AgCl) in op V, after 2 and 28 days, respectively. A reduction of the oxide film resistance, especially in op V (54 MOmega cm(2) and 6 MOmega cm(2) , after 2 and 28 days, respectively) could be seen. Streptococcus mutans negatively affected the corrosion resistance of titanium.

Artículos relacionados

Continúa tu investigación a través de nuestra selección de publicaciones vinculadas. Descubre estudios complementarios que abordan áreas temáticas, enfoques clínicos o desarrollos afines, diseñados para enriquecer tu comprensión sobre este campo científico.

LESIONES NERVIOSAS

The Effectiveness of Plasma Rich in Growth Factors in the Treatment of Nerve Compression Syndromes of the Upper Extremity

Galan V, Inigo-Dendariarena I, Galan J, Prado R, Padilla S, Anitua E. J Clin Med. 2022 Aug 16;11(16):4789.

LESIONES NERVIOSAS

The Effectiveness of Plasma Rich in Growth Factors in the Treatment of Nerve Compression Syndromes of the Upper Extremity

Galan V, Inigo-Dendariarena I, Galan J, Prado R, Padilla S, Anitua E. J Clin Med. 2022 Aug 16;11(16):4789.

LESIONES NERVIOSAS

The Effectiveness of Plasma Rich in Growth Factors in the Treatment of Nerve Compression Syndromes of the Upper Extremity

Galan V, Inigo-Dendariarena I, Galan J, Prado R, Padilla S, Anitua E. J Clin Med. 2022 Aug 16;11(16):4789.

Contacta

Primeiro plano
Nombre *

Apellidos *

Correo electrónico *

¿Cómo quieres que contactemos contigo? *

Teléfono *

Código postal *

País *

Escribe aquí tu consulta *