The aim of this study was to evaluate the influence of the straight alignment versus distal offset placement of an implant-supported prosthesis (using implants with different diameters: 4 mm, 4.5 mm, and 5 mm) on bone stress distribution. 3D finite element models of a straight configuration and different offset configurations of the implant-supported prosthesis (until 2.4 mm distal offset) were evaluated for the three implant diameters. A mesial load of 200 N and a distal load of 230 N were applied to the prosthesis. Results showed that implant offset provokes an opposite effect in bone stress depending on the exposed mesial or distal force. The former increases stress whereas the latter induces a dissipation of bone stress proportional to the offset. From these two forces, an optimal offset is created in which maximum bone stress is reduced in the range of 7-8% compared with the straight configuration. Increasing implant diameter from 4 to 5 mm decreased bone stress in 30% for all configurations. These data suggests that offset implant placement apart from enabling an optimal aesthetic restoration, reduces bone stress compared with the straight configuration. The use of wider implants permitted the reduction of the maximum bone stress in all the simulated configurations.
— actualidad · noticias ›
miércoles, 10 de junio de 2026
BTI Biotechnology Institute vuelve a situarse como la empresa biotecnológica española con mayor producción científica, con un total de 29 publicaciones recogidas en el Informe AseBio 2025.
2,009
The aim of this study was to evaluate the influence of the straight alignment versus distal offset placement of an implant-supported prosthesis (using implants with different diameters: 4 mm, 4.5 mm, and 5 mm) on bone stress distribution. 3D finite element models of a straight configuration and different offset configurations of the implant-supported prosthesis (until 2.4 mm distal offset) were evaluated for the three implant diameters. A mesial load of 200 N and a distal load of 230 N were applied to the prosthesis. Results showed that implant offset provokes an opposite effect in bone stress depending on the exposed mesial or distal force. The former increases stress whereas the latter induces a dissipation of bone stress proportional to the offset. From these two forces, an optimal offset is created in which maximum bone stress is reduced in the range of 7-8% compared with the straight configuration. Increasing implant diameter from 4 to 5 mm decreased bone stress in 30% for all configurations. These data suggests that offset implant placement apart from enabling an optimal aesthetic restoration, reduces bone stress compared with the straight configuration. The use of wider implants permitted the reduction of the maximum bone stress in all the simulated configurations.
Selecciona el cuadro de debajo y mapéalo al campo «A quién va dirigido» del contenido actual. Cada párrafo o elemento de lista se mostrará como una tarjeta.
En BTI Biotechnology Institute, la investigación es el motor que transforma el conocimiento en soluciones clínicas reales. Avalados por más de una década liderando la producción científica biotecnológica en España y con más de 350 artículos publicados, nuestro compromiso es puramente traslacional: llevar cada descubrimiento del laboratorio directamente a la práctica médica diaria para mejorar la calidad de vida de los pacientes.
Para hacerlo posible, contamos con instalaciones de vanguardia preparadas para la máxima exigencia. En este entorno de alto rendimiento, nuestro equipo desarrolla tecnologías revolucionarias, como los avanzados sistemas de implantología o el plasma rico en factores de crecimiento (PRGF-Endoret®). Descubre cómo nuestro rigor científico nos permite innovar de forma personalizada, no solo en cirugía oral, sino en áreas tan diversas como la oftalmología, la traumatología, la medicina deportiva o la dermatología.
¡Gracias!